SEW變頻器MOVITRAC-07系列故障代碼詳表

發布時間:2019-08-02 15:40:24來源:

故障代碼 故障現象/類型 故障原因 解決對策
01 Over-current • Short circuit on output • Output switching • Motor too large • Defective output stage • Ramp limit (P138) switched off • Rectify the short circuit • Only switch when output stage inhibited • Connect a smaller motor • Call SEW Service for advice if the fault still cannot be reset • Ramp limit (P138 = YES)
03 Ground fault • Ground fault on motor • Ground fault on inverter • Ground fault in the motor lead • Over-current (see F-01) • Replace the motor • Replace the MOVITRAC® 07 • Rectify the ground fault • See F-01
04 Brake chopper • Regenerative power excessive • Braking resistor circuit interrupted • Short circuit in braking resistor circuit • Excessively high braking resistance • Brake chopper defective • Ground fault • Extend deceleration ramps • Check connecting harness for braking resistor • Rectify the short circuit • Check technical data of braking resistor • Replace the MOVITRAC® 07 • Rectify the ground fault
06 Supply system phase failure (only with three-phase inverter) Phase fault Check supply system lead
07 DC-link overvoltage • DC link voltage too high • Ground fault • Extend deceleration ramps • Check connecting harness for braking resistor • Check technical data of braking resistor • Rectify the ground fault
08 Speed monitoring Current controller is operating at the setting limit due to: • mechanical overload • phase failure in supply system • phase failure in motor • Reduce load • Increase delay time setting P501 • Check current limitation • Extend deceleration ramps • Check supply system phases • Check motor feeder and motor Maximum speed for VFC operating mode exceeded • Reduce load • Increase delay time setting P501 • Check current limitation • Extend deceleration ramps • Check supply system phases • Check motor feeder and motor Maximum speed for VFC operating mode exceeded • Reduce maximum speed
10 ILLOP • Incorrect command during running of program • Incorrect conditions during running of program • Function not in inverter / not implemented • Check program • Check program structure • Use another function
11 Overtemperature Thermal overload of inverter • Reduce load and/or ensure adequate cooling • If the braking resistor is integrated in the heat sink: Mount the braking resistor externally
17-24 System fault Inverter electronics disrupted, possibly due to effect of EMC Check ground connections and shields; improve them if necessary. Contact SEW Service for advice if this reoccurs.
25 EEPROM Fault when accessing EEPROM Call up default setting, perform reset and set parameters again. Contact SEW Service for advice if this reoccurs.
26 External terminal Read in external fault signal via programmable input Eliminate specific cause of fault; reprogram terminal if appropriate.
31 TF sensor • Motor too hot, TF sensor has tripped • TF sensor of motor not connected or not connected properly • Connection of MOVITRAC® 07 and TF interrupted on motor • Let motor cool down and reset fault • Check connections/links between MOVITRAC® 07 and TF
32 Index overrun Basic programming rules violated causing internal stack overflow Check and correct user program
34 Ramp timeout The inverter signals F34 if you revoke the enable and the drive exceeds the rapid stop ramp time t13 by a certain time. Extend the rapid stop ramp time
37 Watchdog timer Fault in system software sequence Check ground connections and shields; improve them if necessary. Contact SEW Service for advice if this reoccurs.
38 System software System fault Check ground connections and shields; improve them if necessary. Contact SEW Service for advice if this reoccurs.
43 RS-485 timeout Communication between inverter and PC interrupted Check connection between inverter and PC.
44 Unit utilization Unit utilization (Ixt value) excessive • Reduce power output • Extend ramps • If these points are not possible: Use a larger inverter
45 Initialization Error during initialization Contact SEW Service for advice.
47 System bus timeout Fault during communication via system bus Check system bus connection.

故障代碼 故障現象/類型 故障原因 解決對策
77 Control word An external control has attempted to set an invalid automatic mode • Check serial connection to external control • Check write values of external control
81 Start condition Only in "VFC hoist" operating mode: The inverter could not inject the required amount of current into the motor during the pre-magnetization time: • Motor rated power too small in relation to inverter rated power • Motor cable cross section too small • Check connection between inverter and motor • Check startup data and repeat startup if necessary
82 Output open Only in "VFC hoist" operating mode: • Two or all output phases interrupted • Motor rated power too small in relation to inverter rated power Check connection between inverter and PC.
94 EEPROM checksum EEPROM defective Contact SEW Service for advice.
97 Copy fault • Parameter module disconnected during copying process • Switching off/on during copying process Prior to acknowledging the fault: • Load the factory setting or the complete data record from the parameter module
、、、、、、、長治變頻器維修、、、、信陽變頻器維修、、、,河南鄭州變頻器專業銷售維修中心,技術精湛,質量可靠,價格比較低,信譽保證!變頻器維修電話:15515598858 0371-56700815
用手機看
SEW變頻器MOVITRAC-07系列故障代碼詳表

拍下二維碼,信息隨身看

試試用手機掃一掃,
在你手機上繼續觀看此頁面。

主站蜘蛛池模板: 国产成a人片在线观看视频| 精品一区二区三区四区乱码90 | 黄色在线免费网站| 国产乳摇福利视频在线观看| 国产18到20岁美女毛片| 99爱精品视频| 一区二区三区在线观看免费| 波多野给衣一区二区三区| 91综合网| 亚洲欧洲成人| 四虎永久网站| 青青草这里只有精品| 老司机午夜精品视频| 精品视频一区二区三区在线播放| 国产 日韩 欧美 亚洲| 夜夜操操| 四虎免费永久在线播放| 欧美一级免费| 久久免费观看国产精品| 国产自产拍精品视频免费看| 福利视频影院| 中国xxxwww| 午夜免费福利在线观看| 日本一区二区网站| 老司机午夜精品视频你懂的| 国产精品久久久久久久网站| 99热久久这里只精品国产ww| 夜夜爽网站| 日本高中生一级乇片| 久久毛片视频| 成视频年人黄网站免费视频| 又爽又黄又无遮挡的视频在线观看| 性做久久久久免费看| 人成午夜欧美大片免费视频| 久久手机视频| 国产日产精品| www.香蕉网| 亚洲系列中文字幕一区二区 | 九九国产在线视频| 国产成人精品视频一区| 在线看一区|